A via is an essential component of any printed circuit board (PCB), but there are specific requirements and guidelines you should consider when selecting the right via size for your next project. Failure to do so may result in unnecessary delays and costs.
Keep reading for details on PCB via size, including the different types, standard sizes, requirements, and considerations to keep in mind when designing your next project.
A vertical interconnect access (or via) is a plated-through hole in a printed wiring board that is used to route a trace vertically in the board from one layer to another. Through-hole vias can be drilled mechanically, and blind vias are drilled with a laser.
There are three main types of PCB vias:
PCB Via Type vs. Size |
||
Via Type |
Function |
Size Criteria |
| Blind via in-pad | Connects directly to the layer below | 004” to .006” after drilling |
| Buried via | Varies — but must not be less than .008” after plating to facilitate conductive or non-conductive epoxy via fill | Not less than .008” after plating and not more than .018” after plating |
| Through via in-pad | To connect top and bottom layers | Same as above. Pad size must be taken into consideration to meet annular ring requirements |
The most common via size is 10 mil, which is 7 mil after plating, but via size typically depends on the thickness of the board and is considered an aspect ratio equation. Micro vias, both laser drilled and mechanically drilled 4 mil holes, are related to the thickness of the boards. Laser drilled vias, on the other hand, have a requirement to have 3 mils of dielectric spacing between layers.
Size requirements are typically dictated by IPC standards and guidelines. IPC is a nonprofit association for electronics and manufacturing and “leading source for industry standards, training, industry intelligence, and public policy.”
It’s essential to always follow IPC guidelines for PCB technology, which include stipulations such as distance between vias. IPC design guidelines for Class 2, Class 3, Class 3ES, and the military are especially important because they all differ slightly.
In addition to consulting IPC guidelines, keep these questions and considerations in mind:
Vias must be sealed or covered by capped plating. The combination of the sequential build-up of technology and the mechanical processes can disturb the buried via plating, resulting in problems with the board. To prevent this problem, the vias are filled with resin before being plated.
A via in-pad must be plated over because you are placing a component on the pad.